<LOGO>
FM Transmitter Measurement Report
Created: 2024-10-17 18-27-56
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
94.70 MHz 5/5, 61 dBuV SANDELS
Pilot RDS Phase Difference
5.4 kHz 5.5 kHz No phase relation found.
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 1,0 kHz
MIN Hold Max. Samples at Total Samples % above 76,0 kHz
10 kHz 68 kHz 17687 1,5096
Modulation Power
Limit Measuring Tolerance
12,0 dBr 0,2 dBr
MIN AVE MAX % above 12,2 dBr
2,0 dBr 3,48 dBr 4,3 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"SANDELS " 61F1 9 (Varied) 1 0 1 13 --:--
RT
-
AF EON
92.0, 94.7, 106.4, 107.5 MHz -
FM Scope Max at: 68 kHz MIN: 10 kHz % above 76 kHz: 1,5096 Acquired: 2024/10/17 18.26.52 Total samples: 17687 Equivalent time: 0:14:44 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 500 1000
FM Scope MAX: 4,3 dBr MIN: 2,0 dBr AVE: 3,48 dBr % above 12,2 dBr: 0,0 Last value: 3,0 dBr (2024/10/17 18.26.51) 18.12 18.14 18.16 18.18 18.20 18.22 18.24 18.26 0 50 100 Dev. MAX [kHz] 0 2 4 Pm [dBr]